Height | 625mm |
Depth | 670mm |
Width | 870mm |
Weight | 120kg |
Throughput | 270 tests per hour, 450 tests per hour with ISE |
Analyser type | Compact fully automated random access bench top clinical analyser |
Assay type | Endpoint, kinetic and ISE |
Maintenance | Daily maintenance - less than 5 minutes. Simple twice yearly preventative maintenance service |
Data management | Storage of up to 30,000 patient reports, search facility |
Test channels | 50 photometric channels, 3 direct ISE |
Sleep mode | User defined sleep mode capabilities with automatic wash and instrument prep |
Reagent capacity | Removable turntable with 50 cooled positions for 20ml and 70ml bottles |
Reagent cooling | 8 to 15°C |
Reagent identification | Barcode reagent identification |
Reagent inventory | Calculation of remaining reagent volume and tests available Alert for shortage or expired reagents |
Reagent pipette | Dedicated reagent micropipette with liquid level sensor and crash detection |
Sample addition | Sampling interruption for addition of samples |
Sample capacity | 50 positions are contained within the universal carousel, including 10 bespoke positions for calibrators and controls |
Sample dead volume | 150µl in standard or primary tubes, 100µl in paediatric cups |
Sample dilution | Pre-dilution and automatic re-assay with diluted, reduced or increased sample volume |
Sample identification | Barcode sample identification |
Sample pipette | Dedicated sample micropipette with liquid level sensor, crash protection and clot detection |
Sample tube Size | Multiple primary tube sizes (diameter 12 to 16mm, height 55 to 100mm), Paediatric cups |
Sample type | Serum, plasma & urine |
Sample volume | 1.5 to 35µl (0.1µl increments) |
STAT sampling | STAT samples can be added immediately via emergency loading port |
Reaction time | 10 minutes (R1: 5 min. + R2: 5 min.) |
Reaction volume | 100 to 350µl |
Stirring speed | 5 speed levels available |
Stirring system | Dual 5 speed stick type rotating stirrers |
Temperature Control | Dry bath |
Water consumption | Maximum 5 litres per hour |
Water requirements | NCCLS type 1 or 2 purified water supply |
Wash unit | 12 stage washing process |
Cuvettes | 72 semi-permanent cuvettes |
Incubator temperature | 37°C ± 0.1°C |
Cycle time | 13 seconds |
Detector method | Direct absorbance in cuvette (bi-chromatic and monochromatic) |
Detection principal | 12 wavelengths generated via diffraction grating: 340, 380, 415, 450, 510, 546, 570, 600, 660, 700, 750 and 800nm |
ISE unit | Optional ISE unit available |
Light source | Halogen tungsten lamp air cooled by fan |
Quality contro | Interactive Levey-Jennings charts, daily, monthly and batch QC with data archiving |
Calibration principal | Factor, Linear, Point to point, Log-logit, Exponential, Spline and Spline 2 |
Power requirement |
AC100V to 120V, 6.5A (Max.) AC200 to 230V, 3.3A (Max.) 50/60Hz |
Power consumption | 650VA |
Permissable voltage variation | ± 10% (Max.) |
LIMS connectivity | Bi-directional ASTM Standard (RS232 connection) |
Operator interface | Windows® based software |